- myBITZER
- BITZER SOFTWARE
-
ePARTS
ePARTS makes finding the appropriate spare parts for our products fast and easy. The parts are listed according to the model range and appear as a simple zoomable expanded-view drawing. The software is free of charge. As a direct BITZER customer registered at myBITZER, you benefit from additional advanced features – for example, the ability to view online prices of individual spare parts.
ePARTS makes finding the appropriate spare parts for our products fast and easy. The parts are listed according to the model range and appear as a simple zoomable expanded-view drawing. The software is free of charge. As a direct BITZER customer registered at myBITZER, you benefit from additional advanced features – for example, the ability to view online prices of individual spare parts.
- Documentation
- Contact
- Germany (de)
-
Germany (de)
-
Please select country and language:
-
Europe
- Austria / de
- Belarus / en
- Belgium / fr
- Bosnia-Herzegovina / en
- Bulgaria / en
- Croatia / en
- Cyprus / en
- Czech Republic / en
- Denmark / en
- Denmark / dk-en
- Estonia / en
- Finland / en
- France / fr
- Germany / de
- Greece / en
- Hungary / en
- Iceland / en
- Ireland / en
- Italy / it
- Latvia / en
- Lithuania / en
- Luxembourg / fr
- Malta / en
- Netherlands / en
- Norway / en
- Poland / en
- Portugal / pt
- Romania / en
- Russia / ru
- Serbia & Montenegro / en
- Slovakia / en
- Slovenia / en
- Spain / es
- Sweden / en
- Switzerland / de
- Turkey / en
- Ukraine / en
- United Kingdom / en
-
America
- Argentina / es
- Barbados / en
- Belize / en
- Bolivien / es
- Bonaire, Sint Eustatius and Saba / en
- Brazil / pt-br
- Canada / en
- Canada / fr
- Caribbean / en
- Chile / es
- Colombia / es
- Costa Rica / es
- Cuba / es
- Curacao / en
- Dominican Republic / es
- Ecuador / es
- El Salvador / es
- Grenada / es
- Guatemala / es
- Haiti / fr
- Honduras / es
- Jamaika / en
- Mexico / es
- Netherlands Antilles / en
- Nicaragua / es
- Panama / es
- Paraguay / es
- Peru / es
- Puerto Rico / en
- Puerto Rico / es
- Sint Maarten (Dutch part) / en
- Trinidad & Tobago / en
- U.S.A. / us
- Venezuela / es
-
Asia
- Bahrain / en
- Bangladesh / en
- Brunei / en
- China / zh
- Hong Kong SAR of China / en
- India / in-en
- India / en
- Indonesia / en
- Iran / en
- Israel / en
- Japan / ja
- Jordan / en
- Kuwait / en
- Lebanon / en
- Malaysia / en
- Maldives / en
- Myanmar / en
- Oman / en
- Pakistan / en
- Philippines / en
- Qatar / en
- Saudi Arabia / en
- Singapore / en
- South Korea / ko
- Sri Lanka / en
- Syria / en
- Thailand / en
- U.A.E. / en
- Vietnam / en
- Yemen / en
-
Africa
- Algeria / fr
- Angola / pt
- Botswana / en
- Cameroon / fr
- Cameroon / en
- Democratic Republic of Congo (DRC) / fr
- Djibouti / fr
- Egypt / en
- Equatorial Guinea / es
- Equatorial Guinea / pt
- Equatorial Guinea / fr
- Ethiopia / en
- Ghana / en
- Kenya / en
- Lesotho / en
- Libya / en
- Madagascar / fr
- Malawi / en
- Mauritius / en
- Morocco / en
- Mozambique / pt
- Namibia / en
- Nigeria / en
- Reunion / fr
- Senegal / fr
- Seychelles / en
- Seychelles / fr
- South Africa / en
- Sudan / en
- Swaziland / en
- Tanzania / en
- Tunisia / en
- Uganda / en
- Zambia / en
- Zimbabwe / en
-
Australia
-
- Australia / en
- New Zealand / en
-
IQ MODULE CM-RC-02
Relevant documentation
For detailed information and the wiring diagrams for electrical installation, please consult the KT-240 technical information for the compressor module and the AT-300 document on wiring diagrams, which can be found here and under BITZER SOFTWARE.
KT-240 // Technical information: Compressor module for reciprocating compressors IQ MODULE
KT-241-2 // Technical information: Extension board A for compressor module CM-RC-02 of reciprocating compressors IQ MODULE
KT-242-2 // Technical information: Extension board B for compressor module CM-RC-02 of reciprocating compressors IQ MODULE
KB-100-2 // Operating instructions: Semi-hermetic reciprocating compressors
KB-120-9 // Operating instructions: Semi-hermetic reciprocating compressors for subcritical R744 applications
KB-130-9 // Operating instructions: Semi-hermetic reciprocating compressors for transcritical R744 applications
KB-206 // Operating instructions: ECOLITE Air-cooled condensing units with capacity-controlled ECOLINE compressors
AT-300 // Technical information: Schematic wiring diagrams for BITZER products
3D - drawings
ECOLINE
CE1
2kes_2jes_2hes_2ges_2fes
CE2
2ees_2des_2ces
CE3
4fes_4ees_4des_4ces_4bes.zip
CE4
4ve-s_4te-s_4pe-s_4ne-s.zip
BE5
4je_4he_4ge_4fe.zip
BE6
6je_6he_6ge_6fe.zip
CE8
8ge_8fe.zip
CO₂ subcritical
CH1
2nsl_2msl_2ksl_2jsl_2hsl
CH2
2esl_2dsl_2csl
CH3
4fsl_4esl_4dsl_4csl
CME1
2mme-2dme
CME2
2mme-2dme
CME3
4fme_4eme_4dme.zip
CME4
4tme_4pme.zip
CME5
6tme_6pme.zip
CO₂ transcritical
CKHE2
2mte_2kte
CKHE3
4pte_4mte_4kte.zip
CKHE4
4jte_4hte_4gte_4fte_4dte_4cte.zip
CKHE5
6fte_6dte_6cte.zip
CKHE7
8fte_8cte.zip
QUICK START GUIDES
Two operation modes:
- Replacing SE-B with CM-RC-02 in compressor protection mode
This document describes the replacement of SE-B protection devices with CM-RC-02 and the possibilities in compressor protection mode
Download
- Setting and operation in compressor operating mode
This document describes the options and minimum requirements for operation in compressor operating mode
Download
Frequently asked questions (FAQ)
Here you find some frequently asked questions. In case of further questions, please contact us.
Contact
-
What is preconfigured on the IQ MODULE CM-RC-02 ex-factory?
The IQ MODULE CM-RC-02 will be send out ex-factory with the newest Firmware Version. The Compressor type and compressor serial number are preconfigured on the device.Additionally for the compressor operation mode, the default refrigerant and the motor starter function part winding is preselected. Without an extension board ordered accessory will be configured but not mounted/wired.
-
When is the refrigerant type selection needed?
The refrigerant type is necessary, when pressure transducers are mounted on the IQ MODULE CM-RC-02. For the calculation of temperatures based on the measured pressure values, the refrigerant type is needed.
-
Is it possible to change the operation mode on the IQ MODULE CM-RC-02 after shipment?
Yes, for BEST and BEST APP a configuration parameter in the user menu is available. The user can changed between the protection mode (SE-B) and the compressor operation mode.
-
Will the IQ MODULE CM-RC-02 available as 24V variant?
The IQ MODULE CM-RC-02 will not be available as 24 V variant. For 24V systems the SE-B 24V variant will still be available.
-
What voltage is needed for the Safety chain input on the IQ MODULE CM-RC-02?
For the Safety Chain Input a power supply of 115V..230 V is needed.
-
Will the positions of the in/out connections be maintained as on the old models?
The CM-RC-02 with extension board Premium can replace all the functions of CM-RC-01 as the same in- and outputs are supported. The positioning of the in- an outputs are slightly changed. The wire length of the sensors and actors do not need to be adapted.
-
Will the compressor fixing points distances be the same as the old models?
The mounting position of the module housing will be the same. The Module itself has new fixing points and therefor the need of the updated module housing.
-
Will the CE3S family only have an increase in the dimensions of the electrical box in the 3 dimensions, while on the other families we "only" have an increase in the height of the box?
Yes, only CE3S will have an adapted motor terminal box.
-
What is the HP switch contact a kind of relay. Is it a reed contact?
It is a relays contact. Same type of relays also used for the motor contactors and status output.
-
Are Modbus addresses the same as with the CM-RC-01?
Yes, same register address for all existing Modbus Parameter. Additionally, implementation of the CM-RC-02 regarding start, stop, reset status word is exactly the same as for the CM-RC-01 to ensure an easy switch CM-RC-01 to CM-RC-02.
-
Can a PTC140 discharge gas temperature sensor used in combination with IQ MODULE CM-RC-02?
Yes, the PTC140 Sensor can be implemented in row with the PTC Sensor for the motor temperature monitoring.
-
When a new compressor is ordered to replace an old one, can the IQ MODULE CM-RC-02 in protection mode (SE-B) be integrated without modification from the electrical diagram?
Yes, the same inputs and outputs are available on the IQ MODULE CM-RC-02. A rewiring on the system side is not necessary.
A detailed description can be found in the "Quick Start Guides and "How to Videos". A protective earth connection must be fitted in accordance to KB-100. -
Is it possible to implement the IQ MODULE CM-RC-02 with 0..10V signal for VARISTEP?
Yes, the IQ MODULE CM-RC-02 can either be operated with a digital start/stop signal and 0..10V analog signal or via Modbus when VARISTEP is connected.