BITZER - Logo
  • myBITZER
  • BITZER SOFTWARE
  • ePARTS

    ePARTS makes finding the appropriate spare parts for our products fast and easy. The parts are listed according to the model range and appear as a simple zoomable expanded-view drawing. The software is free of charge. As a direct BITZER customer registered at myBITZER, you benefit from additional advanced features – for example, the ability to view online prices of individual spare parts.

    ePARTS makes finding the appropriate spare parts for our products fast and easy. The parts are listed according to the model range and appear as a simple zoomable expanded-view drawing. The software is free of charge. As a direct BITZER customer registered at myBITZER, you benefit from additional advanced features – for example, the ability to view online prices of individual spare parts.

  • Documentation
  • Contact
  • Germany (de)
  • Company
      • About us
      • BITZER worldwide
      • Group Companies
    • Purchasing and Logistics
      • Purchasing Philosophy
      • Supplier application
      • Downloads
      • BITZER goes Ariba
  • Solutions
      • Refrigeration
      • Air Conditioning and Process Cooling
      • Heat pumps
      • Transport
  • Products
      • Reciprocating Compressors
      • Screw Compressors
      • Scroll Compressors
      • Condensing Units
      • Heat Exchangers and Pressure Vessels
      • Ammonia Compressor Packs
      • Electronic Components
    • Tools & Archive
      • Software
      • Apps
      • Refrigerant Report
      • Original or Counterfeit?
      • Product Archive
  • Service
      • SCHAUFLER Academy Trainings & Seminars
      • ORIGINAL SPARE PARTS
      • After Sales & Repair
      • Warranty Management
      • BITZER Services
  • News
      • Press releases
      • Press materials
      • Trade Fairs
      • BITZER magazine
      • Download
  • Career
      • BITZER as an employer
      • Job portal
      • FAQ
    • Career Groups
      • Training and Education
      • Career Starters
      • Experienced Professionals
      • Refrigeration and Air Conditioning Professionals
      • Trainee & Master Thesis
BITZER - Logo
  • Germany (de)
    • Please select country and language:

    • Europe
      • Austria / de‎
      • Belarus / en‎
      • Belgium / fr
      • Bosnia-Herzegovina / en‎
      • Bulgaria / en‎
      • Croatia / en‎
      • Cyprus / en‎
      • Czech Republic / en‎
      • Denmark / en‎
      • Denmark / dk-en‎
      • Estonia / en‎
      • Finland / en‎
      • France / fr‎
      • Germany / de‎
      • Greece / en‎
      • Hungary / en‎
      • Iceland / en‎
      • Ireland / en‎
      • Italy / it‎
      • Latvia / en‎
      • Lithuania / en‎
      • Luxembourg / fr
      • Malta / en‎
      • Netherlands / en
      • Norway / en‎
      • Poland / en‎
      • Portugal / pt‎
      • Romania / en‎
      • Russia / ru
      • Serbia & Montenegro / en‎
      • Slovakia / en‎
      • Slovenia / en‎
      • Spain / es‎
      • Sweden / en‎
      • Switzerland / de‎
      • Turkey / en‎
      • Ukraine / en‎
      • United Kingdom / en‎
    • America
      • Argentina / es‎
      • Barbados / en‎
      • Belize / en‎
      • Bolivien / es‎
      • Bonaire, Sint Eustatius and Saba / en‎
      • Brazil / pt-br
      • Canada / fr‎
      • Canada / en‎
      • Caribbean / en‎
      • Chile / es‎
      • Colombia / es‎
      • Costa Rica / es‎
      • Cuba / es‎
      • Curacao / en‎
      • Dominican Republic / es‎
      • Ecuador / es‎
      • El Salvador / es‎
      • Grenada / es‎
      • Guatemala / es‎
      • Haiti / fr‎
      • Honduras / es‎
      • Jamaika / en‎
      • Mexico / es‎
      • Netherlands Antilles / en‎
      • Nicaragua / es‎
      • Panama / es‎
      • Paraguay / es‎
      • Peru / es‎
      • Puerto Rico / es‎
      • Puerto Rico / en‎
      • Sint Maarten (Dutch part) / en‎
      • Trinidad & Tobago / en‎
      • U.S.A. / us
      • Venezuela / es‎
    • Asia
      • Bahrain / en‎
      • Bangladesh / en‎
      • Brunei / en‎
      • China / zh
      • Hong Kong SAR of China / en‎
      • India / en‎
      • India / in-en‎
      • Indonesia / en‎
      • Iran / en‎
      • Israel / en‎
      • Japan / ja
      • Jordan / en‎
      • Kuwait / en‎
      • Lebanon / en‎
      • Malaysia / en‎
      • Maldives / en‎
      • Myanmar / en‎
      • Oman / en‎
      • Pakistan / en‎
      • Philippines / en‎
      • Qatar / en‎
      • Saudi Arabia / en‎
      • Singapore / en‎
      • South Korea / ko‎
      • Sri Lanka / en‎
      • Syria / en‎
      • Taiwan / en‎
      • Thailand / en‎
      • U.A.E. / en‎
      • Vietnam / en‎
      • Yemen / en‎
    • Africa
      • Algeria / fr‎
      • Angola / pt‎
      • Botswana / en‎
      • Cameroon / fr‎
      • Cameroon / en‎
      • Democratic Republic of Congo (DRC) / fr‎
      • Djibouti / fr‎
      • Egypt / en‎
      • Equatorial Guinea / es‎
      • Equatorial Guinea / pt‎
      • Equatorial Guinea / fr‎
      • Ethiopia / en‎
      • Ghana / en‎
      • Kenya / en‎
      • Lesotho / en‎
      • Libya / en‎
      • Madagascar / fr‎
      • Malawi / en‎
      • Mauritius / en‎
      • Morocco / en‎
      • Mozambique / pt‎
      • Namibia / en‎
      • Nigeria / en‎
      • Reunion / fr‎
      • Senegal / fr‎
      • Seychelles / en‎
      • Seychelles / fr‎
      • South Africa / en‎
      • Sudan / en‎
      • Swaziland / en‎
      • Tanzania / en‎
      • Tunisia / en‎
      • Uganda / en‎
      • Zambia / en‎
      • Zimbabwe / en‎
    • Australia
         
      • Australia / en
      •   
      • New Zealand / en
Products Heat Exchangers and Pressure Vessels Shell and Tube Evaporators Dry-expansion evaporators SQD evaporators
SQD

SQD

On the notepad
No alt text specified
No alt text specified
No alt text specified
No alt text specified
No alt text specified

SQD

On the notepad

The only square design and the most efficient dry-expansion evaporator available on the market. Designed for process cooling and air conditioning duties where operating at low approaches between water leaving temperatures and evaporation temperature is a must. SQD is a family of single-pass heat exchangers including eight different shell widths and many tube length variants in order to fit practically any duty, helping system manufacturers to comply with challenging minimum efficiency targets set by international regulations such as EcoDesign.

Refrigerants

  • Optimised for R134a, R1234ze, R513A
  • Operation approved with all commonly used HFC, HFC/HFO blends, HFO and propane

Capacity range

  • Cooling capacity up to 2000 kW

Certifications:

  • CE (PED 2014/68/EU)
  • EAC
  • SELO/CML

Submit request
  • Features
  • Benefits
  • Accessories

Patented refrigerant distribution system

  • Perfect distribution of liquid in all the tubes
  • Superheating optimisation
  • Compatibility with most used HFO and HFC/HFO blends

Single-pass, countercurrent concept

  • Refrigerant and water use the most efficient flow concept: countercurrent
  • Single-pass configuration on refrigerant side reduces pressure drop

Multicircuit design

  • One, two or three independent refrigerant circuits
  • Maximum safety of operation as in case of forced stop of one circuit; the others continue to work
  • Increased part load efficiency

Revolutionary square design

  • Higher heat exchange surface compared to traditional cylindrical dry-expansion evaporators
  • Optimised water side flow
  • High level of customisation

Helping to reach EcoDesign Tier II efficiency targets

Thanks to its high performance and the possibility to reach very compact thermal approaches between the water leaving temperature and the evaporation temperature, SQD is the solution allowing chiller manufacturers to reach the challenging minimum efficiency targets of EcoDesign Tier II for air conditioning and process cooling applications.

Dry-expansion solution: less refrigerant charge

Ensuring performance close to that typical of a flooded evaporator, SQD uses a dramatically reduced refrigerant charge.

Oil recovery? Not a problem

Oil flow through the evaporator is always guaranteed.

Flexibility in part load operation

SQD allows the possibility of playing with one to three independent refrigerant circuits, and – at the same time – operating in part load up to 25% in each single circuit.

Optimisation of water pumping costs

The number of baffle choices allows the optimisation of water-side pressure drop in all conditions, avoiding penalising pumping costs.

A wide range of options

  • Water connections located on the left or right side of the shell
  • Standard temperature or low temperature (TS< –10°C) versions
  • One, two, three or four refrigerant circuits

A wide range of accessories

  • Welded support feet
  • Thermal insulation
  • Antifreeze heaters
  • Flexible joint (Victaulic) or flanged water connections

  • Features

    Patented refrigerant distribution system

    • Perfect distribution of liquid in all the tubes
    • Superheating optimisation
    • Compatibility with most used HFO and HFC/HFO blends

    Single-pass, countercurrent concept

    • Refrigerant and water use the most efficient flow concept: countercurrent
    • Single-pass configuration on refrigerant side reduces pressure drop

    Multicircuit design

    • One, two or three independent refrigerant circuits
    • Maximum safety of operation as in case of forced stop of one circuit; the others continue to work
    • Increased part load efficiency

    Revolutionary square design

    • Higher heat exchange surface compared to traditional cylindrical dry-expansion evaporators
    • Optimised water side flow
    • High level of customisation

  • Benefits

    Helping to reach EcoDesign Tier II efficiency targets

    Thanks to its high performance and the possibility to reach very compact thermal approaches between the water leaving temperature and the evaporation temperature, SQD is the solution allowing chiller manufacturers to reach the challenging minimum efficiency targets of EcoDesign Tier II for air conditioning and process cooling applications.

    Dry-expansion solution: less refrigerant charge

    Ensuring performance close to that typical of a flooded evaporator, SQD uses a dramatically reduced refrigerant charge.

    Oil recovery? Not a problem

    Oil flow through the evaporator is always guaranteed.

    Flexibility in part load operation

    SQD allows the possibility of playing with one to three independent refrigerant circuits, and – at the same time – operating in part load up to 25% in each single circuit.

    Optimisation of water pumping costs

    The number of baffle choices allows the optimisation of water-side pressure drop in all conditions, avoiding penalising pumping costs.

  • Accessories

    A wide range of options

    • Water connections located on the left or right side of the shell
    • Standard temperature or low temperature (TS< –10°C) versions
    • One, two, three or four refrigerant circuits

    A wide range of accessories

    • Welded support feet
    • Thermal insulation
    • Antifreeze heaters
    • Flexible joint (Victaulic) or flanged water connections

*For further documentation please choose Product Type

Products

SQD15062

Technical Data TO DOCUMENTATION

SQD15072

Technical Data TO DOCUMENTATION

SQD15082

Technical Data TO DOCUMENTATION

SQD15092

Technical Data TO DOCUMENTATION

SQD15102

Technical Data TO DOCUMENTATION

SQD15112

Technical Data TO DOCUMENTATION

SQD15122

Technical Data TO DOCUMENTATION

SQD15132

Technical Data TO DOCUMENTATION

SQD20062

Technical Data TO DOCUMENTATION

SQD20072

Technical Data TO DOCUMENTATION

SQD20082

Technical Data TO DOCUMENTATION

SQD20092

Technical Data TO DOCUMENTATION

SQD20102

Technical Data TO DOCUMENTATION

SQD20112

Technical Data TO DOCUMENTATION

SQD20122

Technical Data TO DOCUMENTATION

SQD20132

Technical Data TO DOCUMENTATION

SQD25062

Technical Data TO DOCUMENTATION

SQD25072

Technical Data TO DOCUMENTATION

SQD25082

Technical Data TO DOCUMENTATION

SQD25092

Technical Data TO DOCUMENTATION

SQD25102

Technical Data TO DOCUMENTATION

SQD25112

Technical Data TO DOCUMENTATION

SQD25122

Technical Data TO DOCUMENTATION

SQD25132

Technical Data TO DOCUMENTATION

SQD30062

Technical Data TO DOCUMENTATION

SQD30072

Technical Data TO DOCUMENTATION

SQD30082

Technical Data TO DOCUMENTATION

SQD30092

Technical Data TO DOCUMENTATION

SQD30102

Technical Data TO DOCUMENTATION

SQD30112

Technical Data TO DOCUMENTATION

SQD30122

Technical Data TO DOCUMENTATION

SQD30132

Technical Data TO DOCUMENTATION

SQD35062

Technical Data TO DOCUMENTATION

SQD35072

Technical Data TO DOCUMENTATION

SQD35082

Technical Data TO DOCUMENTATION

SQD35092

Technical Data TO DOCUMENTATION

SQD35102

Technical Data TO DOCUMENTATION

SQD35112

Technical Data TO DOCUMENTATION

SQD35122

Technical Data TO DOCUMENTATION

SQD35132

Technical Data TO DOCUMENTATION

SQD40062

Technical Data TO DOCUMENTATION

SQD40072

Technical Data TO DOCUMENTATION

SQD40082

Technical Data TO DOCUMENTATION

SQD40092

Technical Data TO DOCUMENTATION

SQD40102

Technical Data TO DOCUMENTATION

SQD40112

Technical Data TO DOCUMENTATION

SQD40122

Technical Data TO DOCUMENTATION

SQD40132

Technical Data TO DOCUMENTATION

SQD45062

Technical Data TO DOCUMENTATION

SQD45072

Technical Data TO DOCUMENTATION

SQD45082

Technical Data TO DOCUMENTATION

SQD45092

Technical Data TO DOCUMENTATION

SQD45102

Technical Data TO DOCUMENTATION

SQD45112

Technical Data TO DOCUMENTATION

SQD45122

Technical Data TO DOCUMENTATION

SQD45132

Technical Data TO DOCUMENTATION

SQD50062

Technical Data TO DOCUMENTATION

SQD50072

Technical Data TO DOCUMENTATION

SQD50082

Technical Data TO DOCUMENTATION

SQD50092

Technical Data TO DOCUMENTATION

SQD50102

Technical Data TO DOCUMENTATION

SQD50112

Technical Data TO DOCUMENTATION

SQD50122

Technical Data TO DOCUMENTATION

SQD50132

Technical Data TO DOCUMENTATION

  • Imprint
  • Privacy
  • Cookie Settings
  • Terms & Conditions
  • Sitemap
Notepad element)elements)