Introduction
Safety
Also observe the following technical documents
Qualified and authorised staff
Residual risks
Personal protective equipment
Safety references
General safety references
Mind with the refrigerant R744
Technical data
Compressor module (K03)
Inputs and outputs for compressor start and operation
Inputs and outputs for peripheral devices
Voltage supply of the peripheral devices
Requirements for connection cables
Cable bushings into the module housing
Technical Data of OLM-IQ actuator sensor unit
Peripheral devices
Standard
Options
Overview: Peripheral devices
Arrangement of the capacity regulators
Retrofittable accessories
The OLM-IQ
Operating and monitoring functions
Operating functions
CRII capacity control
Analogue signal with set point characteristic
Min .. Max
Analogue signal with set point characteristic
0 .. Max
Start unloading
Oil heater
Switching the motor contactors on and off at compressor start
Monitoring and protective functions
Mounting the peripheral devices enclosed in the delivery
Mounting OLM-IQ-AS (B43 and M41)
Electrical connection
Representation of components and cables
Legend for the schematic wiring diagrams
Wiring in the state of delivery
8-cylinder compressors for transcritical R744 applications
High pressure switch (B10)
Connecting cables
Compressor power connection
Required electrical connections on the CM-RC-01
Module power connection to terminal strip CN1
Integrating into safety chain
Motor contactors
Start command for timer
Control signal from superior controller (K01)
Setting the communication for compressor start in FI operation
Connecting the high pressure switch (B10) electrically
Close module housing
Electrical connection of the enclosed peripheral devices
Connecting the OLM-IQ actuator sensor unit (B43 and M41) electrically to the CM-RC-01
Controlling the capacity controller with the system controller
Control via analogue signal
Control via Modbus interface
Preparing the
best
interface converter
Close module housing
Protective functions
Operating status lights
Alarm level and alarm list
Limiter function
Monitored functions
Table information
Switch on and reset
Time-delayed release for automatic switch on (timed reset)
Reset (external reset)
Restart
Monitoring operating parameters with
Best Software
or
Best App
Establishing communication via the
Best software
Setting up communication
Configuring the compressor module with the
Best Software
Setting the current time
Selecting the motor start function
Entering the refrigerant used
Activating peripheral devices
Activating application limits monitoring
Activating high and low pressure switches
Deactivating the Bluetooth interface
Configuring a spare part
Data log
Mind when mounting or replacing
Special screwed connections
Metric screws with standard thread
Screwed nipples: Sensor and prism units
Sealing screws with fine thread, plugs and screwed nipples
Plugs without gasket
Sight glasses and components at sight glass position
Solenoid valves
Electrical contacts
Screwed connections of terminal box and FI housing cover
Sealing screwed connections for the openings into terminal box and module housing