OS.74: Replacing a previous shaft seal through a new version

Previous shaft seal with OS.74

1

stationary unit

2

sealing cover

3

stationary slinding ring

4

O-ring

7

oil drain pipe

9

gasket of sealing cover

10

rotating unit

11

O-ring

12

set screws

13

slot for removal

15

oil orifice

17

oil flow switch

  1. Preparation Removing the shaft seal with metal bellows.
  2. Remove the sealing cover (2) with the stationary unit (1).
  3. Remove the rotating unit (10) and the O-rings (4) and (11).
  4. Remove the oil drain pipe (7) and the gasket of sealing cover (9).
  5. Remove the oil pipe (21) and the angle pipe connection (23).
  6. Reseal the thread of the angled pipe connection (23).
  7. Screw in the angled pipe connection (23) with the opening facing downwards.
  8. Close the connection of the discharge gas side with plug (22).
  9. Select the oil pipe (24):
    longer oil pipe for OS.7471
    shorter oil pipe for OS.7461 and OS.7451.
  10. Remove the plug (26) from the bottom side of the compressor.
  11. If the plug (26) is not present, remove the Schrader valve (25) from the bottom side of the compressor.
  12. Screw in the straight pipe connection (27).
  13. Screw the oil pipe in here and onto the angled pipe connection (23).
  14. See above for mounting the metal bellows shaft seal.
OS.74: Conversion of the oil pipes, side view
OS.74: Conversion of the oil pipes, version 1, view from below
OS.74: Conversion of the oil pipes, version 2, view from below

21

oil pipe of the previous version

22

new plug

23

angle pipe connection

24

new oil pipe

25

Schrader valve

26

plug

27

straight pipe connection

The R717 version OS.A74 has been manufactured without external oil pipes since September 2012.