Coupling KS900 for OS.A95

Sketch

Dimensions:

The KS900 coupling is available with different hub lengths on the motor side (dimension "E" in dimensional drawing) to ensure sufficient torque transmission. (Check torque transmission).

Dimensional drawing KS900
Dimensional drawing KS900

A

B

C

D

E

KS900, bore for shaft D55,
hub length 70
part no. 342 061 01

Ø 55 mm

20 mm

16 mm

59.3 mm

70 mm

KS900, bore for shaft D60,
hub length 70
part no. 342 062 01

Ø 60 mm

20 mm

18 mm

64.4 mm

70 mm

KS900, bore for shaft D65,
hub length 80
part no. 342 063 01

Ø 65 mm

20 mm

18 mm

69.4 mm

80 mm

KS900, bore for shaft D65,
hub length 110
part no. 342 064 01

Ø 65 mm

20 mm

18 mm

69.4 mm

110 mm

KS900, bore for shaft D70,
hub length 80
part no. 342 058 01

Ø 70 mm

20 mm

20 mm

74.9 mm

80 mm

KS900, bore for shaft D70,
hub length 110
part no. 342 065 01

Ø 70 mm

20 mm

20 mm

74.9 mm

110 mm

KS900, bore for shaft D75,
hub length 110
part no. 342 060 01

Ø 75 mm

20 mm

20 mm

79.9 mm

110 mm

KS900, bore for shaft D80,
hub length 80
part no. 342 058 02

Ø 80 mm

20 mm

22 mm

85.4 mm

80 mm

KS900, bore for shaft D80,
hub length 110
part no. 342 066 01

Ø 80 mm

20 mm

22 mm

85.4 mm

110 mm

KS900, bore for shaft D20, pre-drilled,
hub length 70
part no. 442 062 01

Ø 20 mm

20 mm

–

–

70 mm

KS900, bore for shaft D20, pre-drilled,
hub length 80
part no. 442 058 01

Ø 20 mm

20 mm

–

–

80 mm

KS900, bore for shaft D20, pre-drilled,
hub length 110
part no. 442 060 01

Ø 20 mm

20 mm

–

–

110 mm

Connection positions

Connection positions

1

Compressor side

2

Motor side

3

Compressor shaft

4

Motor shaft

Dimensions (if specified) may have tolerances according to EN ISO 13920-B.

The legend applies to all BITZER couplings and includes connection positions that do not exist in every series.

If the motor is different, an individual design of coupling and housing is necessary!

If the motor is different, an individual design of coupling and housing is necessary!

Make sure that the torque transmission between the motor shaft and the coupling half in contact is sufficient (Check torque transmission).

Overview of the couplings KS900 with different bores and hub lengths