Electrical contacts
DANGERDanger of electrical shock!

Danger of electrical shock!
Disconnect supply voltage and secure it against being switched on again!
- Transfer cable markings when cutting to length.
Contacts at terminal plate
These tightening torques also apply to earth connections located next to the terminal plate and earthing the interior of the housing.
Size | Nut | Screw |
|---|---|---|
M4 | 2 Nm | |
M5 | 5 Nm | 2.6 Nm |
M6 | 6 Nm | 14 Nm |
M7 | 7 Nm | |
M8 | 10 Nm | 25 Nm |
M10 | 25 .. 30 Nm | 40 Nm ① |
M12 | 30 .. 35 Nm | 40 Nm ① |
①: Mount with a pair of wedge lock washers.
- Tighten all screwed connections on terminal plate manually with torque spanner to indicated torque.
- Do not use any pneumatically driven tool.
Cable fixing on terminal strips
Size |
|
|---|---|
M2 | 0.25 Nm |
M3 | 0.5 Nm |
M4 | 1.2 Nm |
These tightening torques apply with and without cables.
Terminal strips with a 3.81 mm spacing pitch contain M2 screws and those with a 5.08 mm spacing pitch contain M3 screws.