Semi-hermetic compressors for R744 subcritical

Sound power level (one-third octave bands) and sound pressure levels

The measurements were taken with the refrigerant R744 (CO2) at operating frequency 50 Hz.
Evaporation temperature to = -35°C, condensing temperature tc = -5°C, suction gas superheat Δtoh 10K.
The calculated sound pressure level in the last column refers to free field conditions with hemispherical sound propagation at a distance of 1 m.
The tolerance for all specifications is +/- 2 dB(A).
For the measured quantities and their units: Introduction

Series SL (2NSL .. 4NSL)

Sound power and sound pressure levels for semi-hermetic reciprocating compressors of series SL for subcritical R744 applications.

Compressor

Sound power level in dB(A) at different frequencies (one-third octave band)

Sound pressure level in dB(A)

80 Hz

100 Hz

125 Hz

160 Hz

200 Hz

250 Hz

315 Hz

400 Hz

500 Hz

630 Hz

800 Hz

1000 Hz

1250 Hz

1600 Hz

2000 Hz

2500 Hz

3150 Hz

4000 Hz

5000 Hz

6300 Hz

2NSL-05

20.6

33.2

35.6

34.5

46.1

37.6

37.7

41.4

44.1

53

52.9

57

61.8

61.4

58.2

57.7

52.1

51.7

48.9

46.3

59.5

2MSL-07

21.1

33.7

36.1

35

46.6

38.1

38.2

41.9

44.6

53.5

53.4

57.5

62.3

61.9

58.7

58.2

52.6

52.2

49.4

46.8

60.0

2KSL-1

21.3

33.9

36.3

35.2

46.8

38.3

38.4

42.1

44.8

53.7

53.6

57.7

62.5

62.1

58.9

58.4

52.8

52.4

49.6

47

60.2

2JSL-2

21.6

34.2

36.6

35.5

47.1

38.6

38.7

42.4

45.1

54

53.9

58

62.8

62.4

59.2

58.7

53.1

52.7

49.9

47.3

60.5

2HSL-3

23.1

35.7

38.1

37

48.6

40.1

40.2

43.9

46.6

55.5

55.4

59.5

64.3

63.9

60.7

60.2

54.6

54.2

51.4

48.8

62.0

2GSL-3

23.1

35.7

38.1

37

48.6

40.1

40.2

43.9

46.6

55.5

55.4

59.5

64.3

63.9

60.7

60.2

54.6

54.2

51.4

48.8

62.0

2FSL-4

23.9

36.5

38.9

37.8

49.4

40.9

41

44.7

47.4

56.3

56.2

60.3

65.1

64.7

61.5

61

55.4

55

52.2

49.6

62.8

2ESL-4

24.1

36.7

39.1

38

49.6

41.1

41.2

44.9

47.6

56.5

56.4

60.5

65.3

64.9

61.7

61.2

55.6

55.2

52.4

49.8

63.0

2DSL-5

24.6

37.2

39.6

38.5

50.1

41.6

41.7

45.4

48.1

57

56.9

61

65.8

65.4

62.2

61.7

56.1

55.7

52.9

50.3

63.5

2CSL-6

25.1

37.7

40.1

39

50.6

42.1

42.2

45.9

48.6

57.5

57.4

61.5

66.3

65.9

62.7

62.2

56.6

56.2

53.4

50.8

64.0

4FSL-7

32

44.4

40.6

52.7

57.8

44.6

53.1

60.5

62.5

63.1

64.1

61.6

66

54.9

56.7

57.2

56

48

48.2

48.2

64.0

4ESL-9

32.5

44.9

41.1

53.2

58.3

45.1

53.6

61

63

63.6

64.6

62.1

66.5

55.4

57.2

57.7

56.5

48.5

48.7

48.7

64.5

4DSL-10

32.5

44.9

41.1

53.2

58.3

45.1

53.6

61

63

63.6

64.6

62.1

66.5

55.4

57.2

57.7

56.5

48.5

48.7

48.7

64.5

4CSL-12

34.5

46.9

43.1

55.2

60.3

47.1

55.6

63

65

65.6

66.6

64.1

68.5

57.4

59.2

59.7

58.5

50.5

50.7

50.7

66.5

4VSL-15

36.5

48.9

45.1

57.2

62.3

49.1

57.6

65

67

67.6

68.6

66.1

70.5

59.4

61.2

61.7

60.5

52.5

52.7

52.7

68.5

4TSL-20

37

49.4

45.6

57.7

62.8

49.6

58.1

65.5

67.5

68.1

69.1

66.6

71

59.9

61.7

62.2

61

53

53.2

53.2

69.0

4PSL-25

38.5

50.9

47.1

59.2

64.3

51.1

59.6

67

69

69.6

70.6

68.1

72.5

61.4

63.2

63.7

62.5

54.5

54.7

54.7

70.5

4NSL-30

39

51.4

47.6

59.7

64.8

51.6

60.1

67.5

69.5

70.1

71.1

68.6

73

61.9

63.7

64.2

63

55

55.2

55.2

71.0

Series ME (2MME .. 2DME)

Sound power and sound pressure levels for semi-hermetic reciprocating compressors of series ME for subcritical R744 applications.

Compressor

Sound power level in dB(A) at different frequencies (one-third octave band)

Sound pressure level in dB(A)

80 Hz

100 Hz

125 Hz

160 Hz

200 Hz

250 Hz

315 Hz

400 Hz

500 Hz

630 Hz

800 Hz

1000 Hz

1250 Hz

1600 Hz

2000 Hz

2500 Hz

3150 Hz

4000 Hz

5000 Hz

6300 Hz

2MME-07

20.8

30.5

24

35.5

19.8

38

40.3

45.1

58.1

55.3

57.6

52.1

56.1

62.7

52.9

51.6

50.3

45.2

42.3

40.4

58.6

2KME-1

21.6

31.9

24.1

35.6

20.4

38.1

40.4

45.2

58.2

55.4

57.7

52.2

56.2

62.8

53

51.7

50.4

45.3

42.4

40.5

58.7

2JME-2

20.8

32.8

24.6

36.1

23.5

38.6

41.1

45.7

58.7

55.9

58.2

52.7

56.7

63.3

53.5

52.2

50.9

45.8

42.9

41

59.2

2HME-3

21.4

33

25.9

37.4

27.7

42.8

45.2

47

60

57.2

59.5

54

58

64.6

58.4

53.5

54.7

52.8

44.2

42.3

60.9

2GME-3

21

33.2

26.1

37.6

28

43.4

45.7

47.2

60.2

57.4

59.7

54.2

58.2

64.8

58.5

53.7

54.7

52.9

44.4

42.5

61.1

2FME-4

21.2

33.6

26.9

38.4

31.7

44.2

47.1

48

61

58.2

60.5

55

59

65.6

60.4

54.5

56.9

53.4

45.2

43.3

62.0

2EME-4

21.4

34

26.4

36.3

35.2

49.4

56.8

53.7

58.3

57.8

58.1

54.9

57.5

59.4

64.1

55.4

58.9

59.6

45.9

42.4

61.6

2DME-5

21.3

34.1

26.3

36.4

37.3

49.5

56.9

53.8

58.4

57.9

58.2

55

57.6

59.5

64.2

55.5

59

59.7

46

42.5

61.7