Removing the shaft seal without metal bellows
The shaft seals of the first OS.53 are designed without bellows. If such a shaft seal is removed anyhow, it should be replaced by a bellows seal.

- Loosen the fixing screws of the sealing cover (2) uniformly. Mind the spring tension of the shaft seal!
- Release the sealing cover with light taps of the plastic hammer if necessary.
- Remove the stationary unit (1).
- Remove gasket remains.
NOTICE
Irreversible damage to the shaft is possible.
Irreversible damage to the shaft is possible.
When removing the shaft seal, the shaft may be damaged to such an extent that it can no longer be sealed.
- Pull the rotating unit out very carefully. Do not let it tilt.
- When pulling it out, use two hooks to grip the slot for removal (13).