Explanation of the motorcodes

In consideration of the varoius power supply systems Bitzer offers motors with different operating voltages and frequencies for all compressors. In the following tables the available operating voltages for the specific compressors are listed. To identify the operating voltages and the motor connection, Bitzer adds the motor code to the compressor name.

Explanation of the motor code for reciprocating compressors

Example

For the motor code 40S the following table shows the different motor connections for the respective operating voltages and frequencies:

Voltage range (V)

Nominal voltage (V)

Motor code

Motor connection

Nominal voltage (V)

Voltage range (V)

50 Hz

60 Hz

220-240

230

40S

∆

-

-

380-420

400

40S

Y

460

440-480

Operation with external frequency inverter (FI)

For common applications, BITZER suggests using the standard motors. They are very economical and have a large range of operation.