Overview: Peripheral devices for compressors for transcritical R744 applications

With these compressors, the capacity control simultaneously ensures an unloaded start. Therefore, cylinder heads designed exclusively for start unloading are not available. The 8-cylinder compressor is described in the Technical Information KT-231 and is only listed here for the sake of completeness. This 8-cylinder compressor is only available with four capacity regulators.

CM-RC-01 : Peripheral devices available for compressors for transcritical R744 applications

Reciprocating compressors for transcritical R744 applications

4PTE-6K/6Z .. 4KTE-10K/10Z

4PTEU-6LK/6LZ .. 4KTEU-10LK/10LZ

4JTE-10K/10Z .. 4CTE-30K/30Z

4JTEU-10LK/10LZ .. 4CTEU-30LK/30LZ

6FTE-35K/35Z .. 6CTE-50K/50Z

6FTEU-35LK/35LZ .. 6CTEU-50LK/50LZ

8FTE-100K/100Z .. 8CTE-140K/140Z

Motor temperature monitoring (B03 .. B08)

Standard

Standard

Standard

Standard

Discharge gas temperature sensor (B02)

Standard

Standard

Standard

Standard

Oil heater (E01)

Standard

Standard

Standard

Standard with 230 V

Oil monitoring

Standard: OLC-D1 (B30)

Standard, depending on compressor version: OLC-D1 (B30) or DP-1 (B12)

Standard: DP-1 (B12)

Standard: DP-1 (B12)

Oil level controller OLM-IQ-AS (B43 and M41)

Option

Option

Option

Option

Capacity regulator (M11 to M14)

Options:
CR-1 or
CR-1 and CR-2

Options:
CR-1 or
CR-1 and CR-2

Options:
CR-1 or
CR-1 and CR-2

Standard: CR-1 to CR-4

Application limits monitoring: High pressure transmitter (B50) and low pressure transmitter (B51)

Option

Option

Option

Option