GSD tandems with FI on the secondary compressor (60 Hz)

In each tandem or trio, one compressor is the primary compressor. This should be the compressor with the lowest displacement in the tandem, because it is the first to receive oil from the BAHT header:

To identify the mounting position which is indicated by "primary" and "secondary compressor", please contact Bitzer for the respective compound assembly drawings.

Orbit tandem compounds with 60 Hz supply frequency (=f (fix)) and frequency inverter on the secondary compressor
f (min.): minimum permitted frequency
f (max.): maximum permitted frequency

Primary compressor

f (fix)

Secondary compressor

f (min.)

f (max.)

GSD80295

60 Hz

GSD80385

46 Hz

75 Hz

GSD80295

60 Hz

GSD80421

42 Hz

75 Hz

GSD80295

60 Hz

GSD80485

37 Hz

75 Hz

GSD80385

60 Hz

GSD80421

55 Hz

75 Hz

GSD80385

60 Hz

GSD80485

48 Hz

75 Hz

GSD80421

60 Hz

GSD80485

53 Hz

75 Hz

GSD60120

60 Hz

GSD60137

53 Hz

75 Hz

GSD60120

60 Hz

GSD60154

47 Hz

75 Hz

GSD60137

60 Hz

GSD60154

54 Hz

75 Hz

GSD60120

60 Hz

GSD60182

41 Hz

75 Hz

GSD60137

60 Hz

GSD60182

46 Hz

75 Hz

GSD60154

60 Hz

GSD60182

51 Hz

75 Hz

GSD60120

60 Hz

GSD60235

35 Hz

75 Hz

GSD60137

60 Hz

GSD60235

36 Hz

75 Hz

GSD60154

60 Hz

GSD60235

40 Hz

75 Hz

GSD60182

60 Hz

GSD60235

47 Hz

75 Hz

GSD60120

60 Hz

GSD80295

60 Hz

75 Hz

GSD60137

60 Hz

GSD80295

60 Hz

75 Hz

GSD60154

60 Hz

GSD80295

60 Hz

75 Hz

GSD60182

60 Hz

GSD80295

60 Hz

75 Hz

GSD60120

60 Hz

GSD80385

47 Hz

75 Hz

GSD60137

60 Hz

GSD80385

49 Hz

75 Hz

GSD60235

60 Hz

GSD80295

60 Hz

75 Hz

GSD60154

60 Hz

GSD80385

52 Hz

75 Hz

GSD60120

60 Hz

GSD80421

45 Hz

75 Hz

GSD60137

60 Hz

GSD80421

45 Hz

75 Hz

GSD60182

60 Hz

GSD80385

60 Hz

75 Hz

GSD60154

60 Hz

GSD80421

47 Hz

75 Hz

GSD60182

60 Hz

GSD80421

51 Hz

75 Hz

GSD60120

60 Hz

GSD80485

37 Hz

75 Hz

GSD60235

60 Hz

GSD80385

60 Hz

75 Hz

GSD60137

60 Hz

GSD80485

39 Hz

75 Hz

GSD60154

60 Hz

GSD80485

41 Hz

75 Hz

GSD60235

60 Hz

GSD80421

55 Hz

75 Hz

GSD60182

60 Hz

GSD80485

45 Hz

75 Hz

GSD60235

60 Hz

GSD80485

53 Hz

75 Hz

GSD60120

60 Hz

GSD60120

60 Hz

75 Hz

GSD60137

60 Hz

GSD60137

60 Hz

75 Hz

GSD60154

60 Hz

GSD60154

60 Hz

75 Hz

GSD60182

60 Hz

GSD60182

60 Hz

75 Hz

GSD60235

60 Hz

GSD60235

60 Hz

75 Hz

GSD80295

60 Hz

GSD80295

60 Hz

75 Hz

GSD80385

60 Hz

GSD80385

60 Hz

75 Hz

GSD80421

60 Hz

GSD80421

60 Hz

75 Hz

GSD80485

60 Hz

GSD80485

60 Hz

75 Hz