SE-E5

Protection functions and properties:

 

For relay current 24 V DC, see also information under Relay versions.

Technical data

SE-E5

Unit

Monitoring parameters

Winding temperature

x

Single phase failure winding temperature

x

Cable short-circuit winding temperature

x

Phases

x

Supply voltage versions

Version 1

Supply voltage

110 .. 240

V

Supply voltage tolerance

-10/+10

%

Supply frequency

50 .. 60

Hz

Version 2

Supply voltage

24

V

Supply voltage tolerance

-15/+10

%

Supply frequency

50 .. 60

Hz

Version 3

Supply voltage

24

V

Supply voltage tolerance

-20/+20

%

Supply frequency

0

Hz

Motor supply

Motor voltage

200 .. 690

V

Motor frequency

50 .. 60

Hz

designed for soft starter

-

designed for FI

x

Motor voltage FI operation

83 .. 400

V

Motor frequency FI operation

20 .. 135

Hz

Relay supply

Relay voltage AC

24 .. 240

V

Relay voltage DC

max. 24

V

Relay current

0,02 .. 2,5

A

Relay current 24 V DC (var. 3)

max. 0,01

A

Relay power max.

300

VA

Relay rating

C300

Other data

Approval according to

EN/UL 60730, EN61010

Ambient temperature

-30 .. 70

°C

Max. altitude

4000

m

Quick acting fuse max.

4

A

Enclosure class

IP00

DIN top hat rail 35mm

x

Terminal screws

x

Height

80

mm

Width

68,3

mm

Depth

32,5

mm

Cable length
phase monitoring

300

mm