Valve Di28/DaXX/RX with connection piece

Photos of connection piece and valve body
Sketch of the connection piece

Dimensions:

Examplary sketch of a brazing and welding bush (applies similarly to other brazing and welding connections), showing the dimensions that are relevant for connection to the compressors, pressure vessels and piping:
A: Outside diameter at pipe insertion end
B: Inside diameter at pipe insertion end
C: Pipe stop diameter, stepped
D: Largest diameter at sealing surface, connection diameter e.g. to compressor, pressure vessel or valve
Details of valve Di28/DaXX/RX. Diameters A .. C are those of the included connection piece (part no. 366 000 06).

A

Outside diameter at pipe insertion end

32 mm

B

Inside diameter at pipe insertion end

28,7 mm

C

Pipe stop diameter, stepped

28,2 mm // 26 mm

Thread

1 3/4''–12UN

Diameter of suitable copper brazing pipes

1 1/8'' // 28 mm

Diameter of suitable steel welding pipes

–

Nomenclature of valve body

PS45|DN32|S36|RX|xx|1 3/4-12UN

Connections with the same dimensions are not necessarily interchangeable!

Connections with the same dimensions are not necessarily interchangeable!