Bush DN32 (1 3/4'')

Part no. 365 214 08

Photo

Dimensions:

Examplary sketch of a brazing and welding bush (applies similarly to other brazing and welding connections), showing the dimensions that are relevant for connection to the compressors, pressure vessels and piping:
A: Outside diameter at pipe insertion end
B: Inside diameter at pipe insertion end
C: Pipe stop diameter, stepped
D: Largest diameter at sealing surface, connection diameter e.g. to compressor, pressure vessel or valve
Details of welding bush DN32 (1 3/4''), part no. 365 214 08

A

Outside diameter at pipe insertion end

37,8 mm

B

Inside diameter at pipe insertion end

32 mm

C

Pipe stop diameter, stepped

─

D

Connection diameter

41,8 mm

Diameter of suitable copper brazing pipes

─

Diameter of suitable steel welding pipes

42,4 mm (DN32)

Nomenclature

S|32|1 1/8|37,3|37,3

can be ordered as a spare part with part no.

365 214 08

Connections with the same dimensions are not necessarily interchangeable!

Connections with the same dimensions are not necessarily interchangeable!

There are often bushes, flanges, pipe connections or valves with similar dimensions, but they cannot necessarily be used with the same products (compressors, pressure vessels etc.)! Which connections are available for which product is listed in the corresponding tables.