CS. series

Nominal diameters (DN) are not actual dimensions!

Nominal diameters (DN) are not actual dimensions!

The nominal diameters DN10 .. DN200 only indicate ranges! The number is not a quantifiable unit, it is only indirectly related to the diameters of the connections and should not be used in calculations.

CSV. compressors

Bushes / flanges and shut-off valves for CSV. compressors. The designations and attributions correspond to those in the Bitzer price list.
HP: high pressure side / discharge gas side
LP: low pressure side / suction side
S: standard
O: option

Compressor

Side

Connection at compressor

D64L – 2 5/8" (DN80)

D76L – 3 1/8" (DN80)

D105L – 4 1/8" (DN100)

D108L – 4 1/4" (DN100)

D130,5L

D134L – DN125

CSV.24 .. 26

HP

76 mm // 3 1/8''

O: Valve

S: Bush
O: Valve

LP

DN100

S: Bush
O: Valve

O: Bush
O: Valve

O: Flange
O: Valve

CSV.37 .. 38

HP

DN100

S: Bush
O: Valve

O: Valve

LP

DN125

O: Flange

S: Flange
O: Valve

CSH compressors

Bushes / flanges and shut-off valves for CSH compressors.The designations and attributions correspond to those in the Bitzer price list.
HP: high pressure side / discharge gas side
LP: low pressure side / suction side
S: standard
O: option

Compressor

Side

Connection at compressor

D42L – 1 5/8'' (DN40)

D54L – 2 1/8" (DN50)

D64L – 2 5/8" (DN50/65/ 80)

D76L – 3 1/8" (DN80/100)

D89L – 3 1/2" (DN100)

D105L – 4 1/8" (DN100)

D108L – 4 1/4" (DN100)

D130,5L

D134L

DN125

DN150

CSH(P)6553 .. 6563

HP

42 mm // 1 5/8''

S: Bush
O: Valve

LP

54 mm // 2 1/8''

S: Bush
O: Valve

CSH6583 .. 6593

HP

54 mm // 2 1/8''

S: Bush
O: Valve

LP

64 mm // 2 5/8''

S: Bush
O: Valve

CSH(P)7553 .. 7573

HP

54 mm // 2 1/8''

S: Bush
O: Valve

LP

76 mm // 3 1/8''

O: Bush
O: Valve

S: Bush
O: Valve

CSH(P)7583 .. 7593

HP

54 mm // 2 1/8''

S: Bush
O: Valve

O: Bush
O: Valve

LP

76 mm // 3 1/8''

O: Bush
O: Valve

S: Bush
O: Valve

CSH76

HP

64 mm // 2 5/8''

O: Bush
O: Valve

S: Bush
O: Valve

LP

76 mm // 3 1/8''

S: Bush
O: Valve

CSH(P)85

HP

76 mm // 3 1/8''

O: Bush
O: Valve

S: Bush
O: Valve

LP

DN100

O: Bush
O: Valve

O: Bush
O: Valve

S: Bush
O: Valve

O: Bush
O: Valve

CSH86

HP

76 mm // 3 1/8''

O: Bush
O: Valve

S: Bush
O: Valve

LP

DN100

O: Bush
O: Valve

S: Bush
O: Valve

O: Bush
O: Valve

CSH(P)9553 .. 9573

HP

76 mm // 3 1/8''

O: Valve

S: Bush
O: Valve

LP

DN100

S: Bush
O: Valve

O: Bush
O: Valve

O: Flange

O: Flange

O: Flange
O: Valve

O: Flange
O: Flange + ring
O: Valve

CSH(P)9583 .. 95113

HP

DN100

O: Bush
O: Valve

S: Bush
O: Valve

O: Bush
O: Valve

LP

DN125

O: Flange

O: Flange

S: Flange
O: Valve

O: Flange
O: Flange + ring
O: Valve

CSH9663 .. 9673

HP

76 mm // 3 1/8''

O: Bush
O: Valve

S: Bush
O: Valve

O: Bush

LP

DN100

S: Bush
O: Valve

O: Bush
O: Valve

O: Flange

O: Flange
O: Valve

O: Flange
O: Flange + ring
O: Valve

CSH9683 .. 96113

HP

DN100

O: Bush
O: Valve

S: Bush
O: Valve

O: Bush
O: Valve

LP

DN125

O: Flange

S: Flange
O: Valve

O: Flange
O: Flange + ring
O: Valve

CSW compressors

Bushes / flanges and shut-off valves for CSW compressors. The designations and attributions correspond to those in the Bitzer price list.
HP: high pressure side / discharge gas side
LP: low pressure side / suction side
S: standard
O: option

Compressor

Side

Connection at compressor

D54L – 2 1/8" (DN50)

D64L – 2 5/8" (DN50/65/ 80)

D76L – 3 1/8" (DN80)

D89L – 3 1/2" (DN100)

D105L – 4 1/8" (DN100)

D108L – 4 1/4" (DN100)

D134L

DN125

DN150

DN200

CSW65

HP

54 mm // 2 1/8''

S: Bush
O: Valve

LP

64 mm // 2 5/8''

S: Bush
O: Valve

CSW75

HP

64 mm // 2 5/8''

O: Bush
O: Valve

S: Bush
O: Valve

LP

76 mm // 3 1/8''

S: Bush
O: Valve

CSW85

HP

76 mm // 3 1/8''

O: Bush
O: Valve

S: Bush
O: Valve

LP

DN100

O: Bush
O: Valve

S: Bush
O: Valve

O: Bush
O: Valve

CSW9563 .. 9573

HP

76 mm // 3 1/8''

O: Bush
O: Valve

S: Bush
O: Valve

O: Bush

LP

DN100

S: Bush
O: Valve

O: Bush
O: Valve

O: Flange

O: Flange
O: Valve

O: Flange
O: Flange + ring
O: Valve

CSW9583 .. 95113

HP

DN100

O: Bush
O: Valve

S: Bush
O: Valve

O: Bush
O: Valve

LP

DN125

O: Flange

S: Flange
O: Valve

O: Flange
O: Flange + ring
O: Valve

CSW105

HP

DN150

S: Flange
O: Valve

LP

DN200

S: Flange
O: Valve

CSH2T compressors

Bushes / flanges and shut-off valves for CSH2T compressors. The designations and attributions correspond to those in the Bitzer price list.
HP: high pressure side / discharge gas side
LP: low pressure side / suction side
S: standard
O: option

Compressor

Side

Connection at compressor

D76L – 3 1/8" (DN80)

D105L – 4 1/8" (DN100)

D108L – 4 1/4" (DN100)

DN125

DN150

CSH2T9563 .. 9573

HP

76 mm // 3 1/8''

S: Bush
O: Valve

LP

DN150

O: Flange
O: Valve (not mounted)

S: Flange
O: Valve (not mounted)

CSH2T9583 .. 9593

HP

DN100

S: Bush
O: Valve

O: Bush
O: Valve

LP

DN150

O: Flange
O: Valve (not mounted)

S: Flange
O: Valve (not mounted)