Details on the bushes / flanges

All bushes / flanges are suitable for A1, A2, A2L and A3 refrigerants as well as R717.

Overview of bushes / flanges for screw compressors with part numbers and designation (representation not to scale!)
Overview of bushes / flanges for screw compressors (connections at suction and discharge gas side)
All bushes / flanges are made of steel. For the soldering commections, imperial and metric pipes are mentioned - if compatible.
*: This pipe must be inserted and welded in place.

Part no.

Type

Designation

Nomenclature

Ø A

Ø B

Ø C

Ø D

Wall thickness

Matching brazing pipes

Matching welding pipes

365 321 14

brazing and welding bush

D42L–1 5/8''–DN40–D57

S|42,2|1 5/8|57|49

49 mm

42,2 mm

41,4 mm

57 mm

3,4 mm

1 5/8'' // 42 mm

48,3 mm (DN40)

365 312 04

brazing and welding bush

D42L–1 5/8''–DN40–D70

S|42,2|1 5/8|70|48

48 mm

42,2 mm

41,4 mm

70 mm

2,9 mm

1 5/8'' // 42 mm

48,3 mm (DN40)

365 321 03

brazing and welding bush

D54L–2 1/8''–DN50–D75

S|54,2|2 1/8|75|60

60 mm

54,2 mm

─

75 mm

2,9 mm

2 1/8'' // 54 mm

60,3 mm (DN50)

365 321 23

brazing bush

D64L–2 5/8''–DN50–D88

S|67|2 5/8|75|74

74 mm

67 mm

64,3 mm

75 mm

3,5 mm

2 5/8'' // 64 mm

─

365 321 18

brazing and welding bush

D64L– 2 5/8''–DN65–D105

S|67|2 5/8|105|76

76 mm

67 mm

64,3 mm

105 mm

4,5 mm

2 5/8'' // 64 mm

76,1 mm (DN65)

365 321 05

brazing bush

D76L–3 1/8''–DN80–D105

S|79,6|3 1/8|105|86,5

86,5 mm

79,6 mm

76,3 mm

105 mm

3,45 mm

3 1/8'' // 76 mm

─

365 321 32

brazing and welding bush

D76L–3 1/8''–DN80–D130

S|89|3 1/28|130|79,6

89 mm

79,6 mm

76,3 mm

130 mm

4,7 mm

3 1/8'' // 76 mm

88,9 mm (DN80)

365 321 22

brazing and welding bush

D89L–3 1/2''–DN100–D130

S|89,3|3 1/2|130|100

100 mm

89,3 mm

86 mm

130 mm

5,35 mm

3 1/2'' // 89 mm

88,9 mm (DN80)*

365 321 17

brazing and welding bush

D105L–4 1/8''–DN100–D130

S|105|4 1/8|130|112,5

112,5 mm

105 mm

─

130 mm

3,75 mm

4 1/8''

114,3 mm (DN100)

365 321 21

brazing and welding bush

D108L–4 1/4''–D100–D130

S|108,3|4 1/4|130|114,8

114,8 mm

108,3 mm

─

130 mm

3,25 mm

108 mm

114,3 mm (DN100)

318 348 17

brazing flange

D130,5L

–

147,8 mm

130,5 mm

─

240 mm

8,6 mm

5 1/8'' // 130,2 mm

─

367 208 06

brazing flange

D134L–DN125

–

140 mm

134 mm

127 mm

240 mm

3 mm

5 1/4''

─

367 208 05

welding neck flange

DN125

–

139,7 mm

130 mm

─

240 mm

4,85 mm

─

139,7 mm (DN125)

367 296 02

welding neck flange

DN150

–

168,3 mm

159,3 mm

─

300 mm

4,5 mm

─

168,3 mm (DN150)

365 338 02

welding neck flange
used with fixing ring

DN150

─

168,3 mm

159,3 mm

─

218 mm

4,5 mm

─

168,3 mm (DN150)

367 297 01

welding neck flange

DN200

–

219,1 mm

206,5 mm

─

360 mm

6,3 mm

─

219,1 mm (DN200)