Explanation of model designations

Example for Ecoline reciprocating compressors

4 D E S H - 7 Y - 40S

Number of cylinders
double with tandem, e. g.: 44DES-14Y-40S

4 D E S H - 7 Y - 40S

Identifier for bore x stroke

4 D E S H - 7 Y - 40S

Series identifier
E = Ecoline
C = Octagon
.2, exception: in the penultimate position of the model designation, e.g. in 4Z-20.2Y -40P

4 D E S H - 7 Y - 40S

Identifier for centrifugal lubrication

4 D E S H 7 Y - 40S

Series properties
H = reinforced drive gear
P = for A3 refrigerant
D = higher pressure levels, exception: in third position, e.g.: 4DDC-7Y-40S)

4 D E S H 7 Y - 40S

Motor size

4 D E S H - 7 Y - 40S

Oil charge
Y = polyolester oil
Z = polyalkylene glycol oil
P = poly-alpha-olefin, specifically for hydrocarbon applications
without identification letter: Mineral oil

4 D E S H - 7 Y - 40S

Motor code

Details on motor codes for reciprocating compressors:

Example for CS. screw compressors

CS H P 8573 - 140 Z - 40P

Semi-hermetic compact screw compressor

CS H P 8573 - 140 Z- 40P

Application range

CS H P 8573 - 140 Z- 40P

Series properties
P = for application with A3 refrigerants
2T = for high temperature application

CS H P 8573 - 140 Z- 40P

Housing size

CS H P 8573 - 140 Z- 40P

Compressor execution

CS H P 8573 - 140 Z - 40P

Displacement

CS H P 8573 - 140 Z- 40P

Compressor execution

CS H P 8573 - 140 Z - 40P

Motor size

CS H P 8573 - 140 Z - 40P

Oil charge
Y = Polyolester oil
P = Poly-alpha-olefin
Z = Polyalkylene glycol oil
without identification letter: B320SH

CS H P 8573 - 140 Z - 40P

Motor code

Example for HS. screw compressors

HSK 8581 - 160 - 40P

Semi-hermetic screw compressor

HSK 8581 - 160 - 40P

Application range
K = Air conditioning and medium temperature application
N = Low temperature application

HSK B 8581 - 90 - 40P

Booster design

HSN P 8591 - 160 - 40P

special design for R290 and R1270

HSK 8581 - 160 - 40P

Housing size

HSK 8581 - 160 - 40P

Displacement

HSK 8581 - 160 - 40P

Compressor execution

HSK 8581 - 160 - 40P

Motor size and design

HSK 8581 - 160 - 40P

Motor code

Details on motor codes for screw compressors:

Example for Orbit scroll compressors

GSD 8 0295 V A B 4 3 2

Scroll compressor

GSD 8 0295 V A B 4 3 2

Configuration
E = Economised
S = Vertical
T = Tandem
Y = Trio
M = Mixed
U = Uneven

GSD 8 0295 V A B 4 3 2

Application
D = HFC - R410A
P = Propane - R290
U = Orbit+ (LSPM)

GSD 8 0295 V A B 4 3 2

Series

GSD 8 0295 V A B 4 3 2

Cooling capacity in kBtu/h according to ARI 540

GSD 8 0295 V A B 4 3 2

Oil type
V = PVE
Z = BSG68K

GSD 8 0295 V A B 4 3 2

Application optimisation
A = Air-cooled, A1 refrigerant
W = Water-cooled, A1 refrigerant
L = Air-cooled, A2L or A3 refrigerant
B = Water-cooled, A2L refrigerant

GSD 8 0295 V A B 4 3 2

Connection type
B = Brazed
R = Rotalock

GSD 8 0295 V A B 4 3 2

Motor code

GSD 8 0295 V A B 4 3 2

Protection device

GSD 8 0295 V A B 4 3 2

Design variable

Details on motor codes for scroll compressors: